Print Options

Card layout: ?

← Back to notecard set|Easy Notecards home page

Instructions for Side by Side Printing
  1. Print the notecards
  2. Fold each page in half along the solid vertical line
  3. Cut out the notecards by cutting along each horizontal dotted line
  4. Optional: Glue, tape or staple the ends of each notecard together
  1. Verify Front of pages is selected for Viewing and print the front of the notecards
  2. Select Back of pages for Viewing and print the back of the notecards
    NOTE: Since the back of the pages are printed in reverse order (last page is printed first), keep the pages in the same order as they were after Step 1. Also, be sure to feed the pages in the same direction as you did in Step 1.
  3. Cut out the notecards by cutting along each horizontal and vertical dotted line
To print: Ctrl+PPrint as a list

111 notecards = 28 pages (4 cards per page)

Viewing:

Florida Building Code-Building, 2017 Questions and Answers

front 1

Garages designed and built to accommodate heavy vehicles shall be able to handle weights that exceed

back 1

10,000 pounds

front 2

What is the net cross-sectional area of a rectangular chimney flue that is 12” x 16”?

back 2

131”

front 3

Non-bearing walls and partitions in conventional light-frame construction shall have a MAXIMUM stud spacing of

back 3

24” o.c.

front 4

What is the MINIMUM required width of a pedestrian walkway in front of a construction or demolition site?

back 4

4 feet

front 5

What is the MINIMUM height of a protective barrier or fence enclosing a residential swimming pool?

back 5

48”

front 6

When excavating a hole within 5 feet of the street lot line, the hole shall have a protective barrier with
a MINIMUM height of______

back 6

6 feet.

front 7

In a building that only has one elevator, how long before the elevator shall automatically transfer to standby power after the failure of the normal power supply?

back 7

Within 60 seconds

front 8

Air supported and air inflated structures larger than 1,500 square feet shall have an auxiliary inflation system that is powered by a standby power system. What is the MINIMUM amount of time the standby power system must operate independently?

back 8

4 hours

front 9

Handrails and guards shall be designed to resist a linear load. What is the load amount?

back 9

50 linear pounds per foot

front 10

When vinyl siding is installed horizontally, what is the MAXIMUM fastener spacing?

back 10

16”

front 11

What is the MINIMUM thickness of exterior poured concrete basement and foundation walls with a
MAXIMUM height of 8 feet and assigned to Seismic Design Category D or E?

back 11

7.5”

front 12

Platform lifts used as a component of an accessible route for wheelchairs shall comply with what
ICC Standard?

back 12

A117.1

front 13

Each dwelling unit shall have at least one room that has a MINIMUM square footage of___________

back 13

120 sq. feet.

front 14

When constructing an artificial barricade in the form of a mound or revetment, what is the
MINIMUM required thickness?

back 14

3 feet

front 15

When installing a foundation drain, the drain pipe shall be placed around the exterior of the perimeter and extend what MINIMUM distance beyond the edge of the foundation?

back 15

12”

front 16

What is the MAXIMUM allowed travel distance from a tenant space on an accessible route to
a drinking fountain in a covered mall building?

back 16

300 feet

front 17

What is the MINIMUM design live load for the entire length of a pedestrian covered walkway?

back 17

150 psf

front 18

In a building that contains commercial cooking equipment, what is the MAXIMUM distance that a portable fire extinguisher can be installed from the cooking equipment?

back 18

30 feet

front 19

A residential aircraft hanger building shall have a MAXIMUM height of 20 feet with a MAXIMUM allowed square footage of

back 19

2,000 sq. ft.

front 20

What is the MAXIMUM distance between fasteners on 1/2” gypsum board used for a horizontal diaphragm ceiling?

back 20

7” on center

front 21

In a building that requires a fire command center, the walls shall be of 1-hour fire barrier construction with a MINIMUM dimension of 10 feet and a MINIMUM square footage of______________________

back 21

200 with a minimum dimension of 10 feet.

front 22

What is the MINIMUM size wood column used to support roof and ceiling loads only?

back 22

6” x 8”

front 23

Which of the two following types of mortar which conform to ASTM C270 can be used on glass unit masonry construction?

back 23

S and N

front 24

What MAXIMUM amount of time delay is allowed before a smoke actuated door must close when activated by smoke detectors?

back 24

10 seconds

front 25

In what type of construction are timber footings allowed to be used?

back 25

Type V

front 26

A commercial cooking fire extinguishing system shall have a manual actuation switch located what

back 26

48”

front 27

What is the MINIMUM thickness required for a lightweight, cast-in-place concrete wall to achieve a 1.5 hour-fire- resistance rating?

back 27

3.1”

front 28

What is the MINIMUM compressive strength of concrete after 28 days?

back 28

3,000 psi

front 29

What is the MINIMUM size covered mall building that is required to have a standby power system?

back 29

Greater than 50,000 sq. feet

front 30

What is the MAXIMUM number of elevator cars that can be located in one hoist way enclosure?

back 30

4 cars

front 31

Unless otherwise indicated, what size area shall a concentrated load be considered uniformly distributed over?

back 31

2-1/2 feet by 2-1/2 feet

front 32

What distance above the public right-of-way can an encroachment be mounted and not be limited in size?

back 32

15 feet

front 33

In a building that is classified as an F-1 occupancy, how many water closets are required?

back 33

1 per 100 people

front 34

Family or assisted-use toilet and bathing rooms count toward the required fixtures in an assembly occupancy. In what other type of occupancy do these facilities count toward fixture totals?

back 34

Mercantile

front 35

What is the MINIMUM ceiling height is required for a means of egress?

back 35

7’ 6” feet

front 36

What MINIMUM dimension column would be required to achieve a 4 hour fire-resistance rating using carbonate concrete?

back 36

12”

front 37

What is the MAXIMUM exit access travel distance in a building that is an S-1 occupancy that is with
automatic sprinkler system?

back 37

400 feet

front 38

What is the MAXIMUM height of a penthouse built on a building (other than a Type I building) to contain air conditioning equipment and piping?

back 38

18 feet

front 39

What is the MINIMUM distance above the plane of a roof that sloped glazing or skylights can be mounted on a curb?

back 39

4”

front 40

When a preconstruction load test is conducted, what is the required amount of time the test shall be left in place?

back 40

When a preconstruction load test is conducted, what is the required amount of time the test shall be left in
place?

front 41

What size and type of nails should be used to secure 2” planks?

back 41

16d common

front 42

What is the MAXIMUM size reinforcement bar that can be used with shotcrete?

back 42

No. 5

front 43

What is the MINIMUM number of fasteners that shall be used per wood shake?

back 43

2 fasteners

front 44

What is the MAXIMUM area of a Group U building that is a Type IIA construction?

back 44

19,000 sq. feet

front 45

What MAXIMUM thickness insulating boards can be installed under approved finish flooring when installed using permitted conditions?

back 45

1/2”

front 46

Footings used for a masonry fireplace shall be constructed of cement or solid masonry with a MINIMUM thickness of

back 46

12”

front 47

What is the MAXIMUM size of a tire warehouse before an automatic sprinkler system throughout the building is required?

back 47

20,000 cubic fee

front 48

What is the MINIMUM nominal thickness in at least one direction for wood framing supporting gypsum board or lath?

back 48

2”

front 49

What is the MINIMUM width for an exit passageway or corridor from a mall?

back 49

66”

front 50

Foam plastic spray insulation applied to a sill plate and header in a Type V construction shall have a MAXIMUM thickness of

back 50

3.25”.

front 51

What MINIMUM size sawn or glued-laminated wood beams and girders shall be used for floor framing?

back 51

6” x 10”

front 52

When a pedestrian barrier is required at a construction site, what is the MINIMUM height that the barrier shall be built extending the entire length of the site?

back 52

8 feet

front 53

Buildings that are over 4 stories in height shall have at least one elevator capable of carrying an ambulance stretcher in the horizontal position. What MINIMUM length will the elevator have to be to accommodate the stretcher?

back 53

84”

front 54

Bearing and exterior walls shall have a double top plate. How much offset is required for the end joints of the double top plate?

back 54

24”

front 55

Interior spaces intended for human occupancy shall have a heating system capable of maintaining what level of temperature measured 3 feet off the floor?

back 55

68oF

front 56

A bowling alley shall be designed for a MINIMUM uniformly distributed live floor load of________

back 56

75 psf.

front 57

What is the MINIMUM clear width of each door opening in a commercial building?

back 57

32”

front 58

What is the MAXIMUM allowed number of stories in height for a Group H-4 occupancy in Type IIB
construction?

back 58

3

front 59

What is the MAXIMUM allowed travel distance to toilet facilities in an office building for employees and the public?

back 59

500 feet

front 60

What is the MINIMUM size access opening to a building attic?

back 60

20” x 30”

front 61

What MINIMUM height above a public right-of-way must the lowest part of an awning, including the valance, maintain?

back 61

7’ 0”

front 62

A temporary structure is required to have a permit when it is designed to hold at least 10 occupants and have a square footage in excess of

back 62

120 sq. feet.

front 63

An incinerator room is classified as an incidental accessory occupancy. What is the required separation and/or protection?

back 63

1 hour separation or a fire extinguishing system

front 64

What two types of mortar are approved for laying masonry unit footings?

back 64

Type M or S

front 65

When cement exterior plaster is being applied to a building, the temperature must be above what temperature?

back 65

40oF

front 66

An automatic sprinkler system is required throughout the building in a Group E occupancy when the
fire area exceeds_________________

back 66

12,000 sq. feet.

front 67

Bearing and exterior wall studs shall have a double top plate. How many nails and what size shall be
used on each side of the end joint on the double top plate?

back 67

8 - 16d face nails

front 68

Concrete used for building foundations included in Seismic Design Category A, B or C shall have what
MINIMUM specified compressive strength?

back 68

2,500 psi

front 69

What is the MAXIMUM height for an aircraft control tower built with Type IB construction?

back 69

240 feet

front 70

What is the MAXIMUM thickness of a masonry bed joint for the starting course of block placed over a foundation?

back 70

5/8”

front 71

What MINIMUM lap is required when installing horizontal fiber-cement siding?

back 71

1.25”

front 72

What is the MAXIMUM exit access travel distance on a pedestrian walkway that has both sides at least 50%
open and has an automatic sprinkler system through the entire distance of the walkway installed?

back 72

400 feet

front 73

Glazing in an individual window, either fixed or operable, shall be considered a hazardous location if the exposed area of an individual pane is more than

back 73

9 square feet.

front 74

Manual fire alarm boxes shall be located not more than 5 feet from entry to each exit with a MAXIMUM
distance between additional manual fire alarm boxes of

back 74

200 feet.

front 75

What is the MINIMUM thickness of the concrete footings required for a masonry chimney?

back 75

12”

front 76

The stability of interior finish products shall be applied or fastened in a manner to prevent the product from becoming detached when subjected to room temperatures of _______________.

back 76

200oF for a minimum of 30 minutes.

front 77

What MAXIMUM distance are steps allowed to project into the public right-of-way?

back 77

12”

front 78

What shall be the MINIMUM fire-resistance rating for interior bearing walls in a Type IIA construction?

back 78

1 hour

front 79

Walk-in coolers in un sprinkled buildings shall have a MAXIMUM foam plastic wall thickness of 4” and shall
not exceed an aggregate floor area of___________

back 79

400 sq. feet.

front 80

What is the MAXIMUM flame spread index allowed for fire-retardant-treated wood?

back 80

25

front 81

What is the MINIMUM separation between skylights when measured in a horizontal plane?

back 81

4 feet

front 82

Open web steel joists must be manufactured to specifications from the Steel Joist Institute. Which of the following is NOT a specification from SJI?

back 82

SJI M

front 83

What type of construction is classified as heavy timber?

back 83

Type IV

front 84

What is the MINIMUM width of a walkway for pedestrians passing a construction site?

back 84

48”

front 85

Which of the following buildings would be classified as an A-2 occupancy?

back 85

Restaurants

front 86

What is the MINIMUM fire barrier assembly resistance between fire areas for an S-2 occupancy group?

back 86

2 hours

front 87

What is the MAXIMUM size of a mezzanine compared to the total floor area of the room where the mezzanine is located?

back 87

33%

front 88

What is the MAXIMUM listed flame spread index for wood that has been impregnated with fire retardant
chemicals through the pressure process?

back 88

25

front 89

All of the following products can be stored in an S-2 occupancy EXCEPT

back 89

furniture.

front 90

What is the MINIMUM period of moist curing time required for the second coat of cement plaster?

back 90

48 hours

front 91

What is the MINIMUM clear width of an escalator that provides service to a below-grade transportation station?

back 91

32”

front 92

What is the MAXIMUM flame spread index for foam plastic insulation greater than 4 inches?

back 92

75

front 93

When fiber-cement siding is installed on a building with wood studs, the siding shall be fastened with corrosion-resistant round head smooth shank nails that will penetrate the studs a MINIMUM of_____

back 93

1”.

front 94

Interior wall and ceiling finishes are classified with ASTM E 84. What is the flame spread rating for a Class C finish?

back 94

76-200

front 95

What is the MINIMUM height of a parapet from the point it insects with the roof’s surface to the top of the parapet?

back 95

30”

front 96

Beginning the construction of a new building requires an excavation be dug. The owners of the adjacent buildings must be notified of the upcoming excavation not less than

back 96

10 days prior to the scheduled starting date.

front 97

What MINIMUM amount of glazing is required to give a room natural light?

back 97

8% of the floor area of the room served

front 98

In order to avoid aerodynamic lift, concrete and clay roof tiles shall be single lapped interlocking with a
MINIMUM head lap of not less than_______.

back 98

2”.

front 99

Door hardware shall be mounted what distance MINIMUM and MAXIMUM distance off the finished floor in a public building?

back 99

34” minimum and 48” maximum

front 100

Concrete or masonry walls below grade shall have waterproofing installed from the bottom of the wall to how far above the MAXIMUM height of the ground-water table?

back 100

12”

front 101

What is stamped on construction documents after they have been reviewed by the building department?

back 101

“Reviewed for Code Compliance”

front 102

What is the MAXIMUM thickness of stone veneer that can be anchored directly to masonry, concrete or stud construction?

back 102

10”

front 103

What is the MAXIMUM length of glass sections used in louvered windows or jalousies?

back 103

48”

front 104

Which of the following hazard categories requires barricade construction for explosion control?

back 104

Organic peroxides

front 105

What is the MINIMUM nominal thickness of a chimney wall made with solid masonry units?

back 105

4”

front 106

In what Residential Group R would a residential board and care/assisted living facility be categorized?

back 106

R-4

front 107

Several different types of glazing can be used in handrails and guards. What is the MINIMUM thickness of the glass (no matter what type of glass is used)?

back 107

1/4”

front 108

What is the MINIMUM thickness concrete floor slab when supported directly on the ground?

back 108

3.5”

front 109

Which of the following mechanical systems DOES require a permit?

back 109

Replacement of a complete boiler

front 110

What is the MINIMUM thickness of interior load-bearing walls made of adobe masonry for a one-story building?

back 110

8”

front 111

Micropiles are reinforced with steel or steel casing. What is the largest size micropile available?

back 111

12”