Print Options

Card layout: ?

← Back to notecard set|Easy Notecards home page

Instructions for Side by Side Printing
  1. Print the notecards
  2. Fold each page in half along the solid vertical line
  3. Cut out the notecards by cutting along each horizontal dotted line
  4. Optional: Glue, tape or staple the ends of each notecard together
  1. Verify Front of pages is selected for Viewing and print the front of the notecards
  2. Select Back of pages for Viewing and print the back of the notecards
    NOTE: Since the back of the pages are printed in reverse order (last page is printed first), keep the pages in the same order as they were after Step 1. Also, be sure to feed the pages in the same direction as you did in Step 1.
  3. Cut out the notecards by cutting along each horizontal and vertical dotted line
To print: Ctrl+PPrint as a list

31 notecards = 8 pages (4 cards per page)

Viewing:

Micro Chapter 3

front 1

2) What structure does light pass through after leaving the condenser in a compound light microscope?

A) ocular lens

B) objective lens

C) specimen

D) illuminator

back 1

C) specimen

front 2

3) Which of the following pairs is mismatched?

A) nigrosin - negative stain

B) methylene blue - simple stain

C) acidic dye - capsule stain

D) basic dye - negative stain

E) crystal violet - simple stain

back 2

D) basic dye - negative stain

front 3

4) Which of the following places the steps of the Gram stain in the correct order?

1-Alcohol-acetone

2-Crystal violet

3-Safranin

4-Iodine

A) 1-2-3-4

B) 2-1-4-3

C) 2-4-1-3

D) 4-3-2-1

E) 1-3-2-4

back 3

C) 2-4-1-3

front 4

5) Which of the following pairs is mismatched?

A) alcohol-acetone — decolorizer

B) crystal violet — basic dye

C) safranin — acid dye

D) iodine — mordant

E) carbolfuchsin — basic dye

back 4

C) safranin — acid dye

front 5

6) Which of the following is NOT true regarding the acid-fast stain?

A) It is used to identify members of the genus Mycobacterium.

B) Acid-fast cells retain the primary dye after treatment with acid-alcohol.

C) If cells are acid-fast, they are gram-negative.

D) Acid-fast cells appear red in a completed acid-fast stain.

E) Non-acid-fast microbes appear blue in a completed acid-fast stain.

back 5

C) If cells are acid-fast, they are gram-negative.

front 6

7) The purpose of a mordant in the Gram stain is to

A) remove the simple stain.

B) make the bacterial cells larger.

C) make the flagella visible.

D) prevent the crystal violet from leaving the cells.

E) make gram-negative cells visible.

back 6

D) prevent the crystal violet from leaving the cells.

front 7

8) Which of the following places the steps in the correct sequence?

1-Staining

2-Making a smear

3-Fixing

A) 1-2-3

B) 3-2-1

C) 2-3-1

D) 1-3-2

E) The order is unimportant.

back 7

C) 2-3-1

front 8

9) The negative stain is used to

A) visualize endospores.

B) determine Gram reaction.

C) determine flagella arrangement.

D) visualize capsules.

E) determine cell size.

back 8

E) determine cell size.

front 9

10) Simple staining is often necessary to improve contrast in which microscope?

A) compound light microscope

B) phase-contrast microscope

C) darkfield microscope

D) fluorescence microscope

E) electron microscope

back 9

A) compound light microscope

front 10

11) Which microscope is used to see internal structures of cells in a natural state?

A) compound light microscope

B) phase-contrast microscope

C) darkfield microscope

D) fluorescence microscope

E) electron microscope

back 10

B) phase-contrast microscope

front 11

12) Which microscope uses visible light?

A) confocal microscope

B) differential interference contrast microscope

C) fluorescence microscope

D) scanning acoustic microscope

E) scanning electron microscope

back 11

B) differential interference contrast microscope

front 12

13) Which microscope achieves the highest magnification and greatest resolution?

A) compound light microscope

B) phase-contrast microscope

C) darkfield microscope

D) fluorescence microscope

E) electron microscope

back 12

E) electron microscope

front 13

14) In using this microscope, the observer does NOT look directly at an image through a lens.

A) compound light microscope

B) phase-contrast microscope

C) darkfield microscope

D) fluorescence microscope

E) electron microscope

back 13

E) electron microscope

front 14

16) A virus measures 100 nm in length. What is its length in μm?

A) 10 μm

B) 1 μm

C) 0.1 μm

D) 0.01 μm

E) 0.001 μm

back 14

C) 0.1 μm

front 15

18) A microorganism measures 5 μm in length. Its length in mm would be

A) 500 mm.

B) 50 mm.

C) 0.5 mm.

D) 0.05 mm.

E) 0.005 mm.

back 15

E) 0.005 mm.

front 16

19) Which of the following correctly traces the path of light through the compound microscope?

A) light source; condenser; specimen; objective lens; ocular lens

B) condenser; light source; specimen; ocular lens; objective lens

C) light source; specimen; condenser; objective lens; ocular lens

D) condenser; light source; specimen; objective lens; ocular lens

E) light source; condenser; objective lens; specimen; ocular lens

back 16

A) light source; condenser; specimen; objective lens; ocular lens

front 17

In Figure 3.1, line "c" points to the microscope's

A) illuminator.

B) condenser.

C) ocular lens.

D) objective lens.

back 17

B) condenser.

front 18

23) Which microscope is most useful for visualizing a biofilm?

A) compound light microscope

B) phase-contrast microscope

C) fluorescence microscope

D) scanning acoustic microscope

E) transmission electron microscope

back 18

D) scanning acoustic microscope

front 19

25) You are performing a Gram stain on gram-positive bacteria and you stop after the addition of the first dye. What is the appearance of the bacteria at this point?

A) purple

B) red

C) colorless

D) brown

back 19

A) purple

front 20

26) You are performing a Gram stain on gram-negative bacteria and you stop after the addition of the mordant. What is the appearance of the bacteria at this point?

A) purple

B) red

C) colorless

D) brown

back 20

A) purple

front 21

27) You are performing a Gram stain on gram-negative bacteria and you stop after the decolorizer step. What is the appearance of the bacteria at this point?

A) purple

B) red

C) colorless

D) brown

back 21

C) colorless

front 22

28) You are performing a Gram stain on gram-positive bacteria and you stop after the addition of the counterstain. What is the appearance of the bacteria at this point?

A) purple

B) red

C) colorless

D) brown

back 22

A) purple

front 23

29) Which type of stain is most useful in helping clinicians to decide which antibiotic to prescribe for a bacterial infection?

A) negative stain

B) simple stain

C) Gram stain

D) endospore stain

E) flagella stain

back 23

C) Gram stain

front 24

31) What is the total magnification of a specimen viewed with a 10x ocular lens and a 45x objective lens?

A) 4.5x

B) 10x

C) 45x

D) 100x

E) 450x

back 24

E) 450x

front 25

36) Which microscope is used to see detail of a 300-nm virus?
A) fluorescence microscope
B) phase-contrast microscope
C) darkfield microscope
D) DIC microscope
E) electron microscope

back 25

E) electron microscope

front 26

38) Which step in the Gram stain is the critical step in differentiating gram-positive cells from gram-negative cells?

A) safranin

B) alcohol-acetone

C) iodine

D) crystal violet

back 26

B) alcohol-acetone

front 27

40) Which microscope is best used for observing the surfaces of intact cells and viruses?

A) phase-contrast microscope

B) darkfield microscope

C) fluorescence microscope

D) brightfield microscope

E) scanning electron microscope

back 27

E) scanning electron microscope

front 28

41) Bacterial smears are fixed before staining to

A) affix the cells to the slide.

B) make their walls permeable.

C) accept stain.

D) make the cells visible.

back 28

A) affix the cells to the slide.

front 29

43) A student is looking at a bacterial specimen using the oil immersion lens, but has forgotten to put immersion oil on the slide. The specimen will appear

  1. A) smaller than it would if immersion oil was used.
  2. B) larger than it would if immersion oil was used.
  3. C) somewhat fuzzy and have poor resolution.
  4. D) the same as it would if the immersion oil was used.
  5. E) to have no color.

back 29

  1. C) somewhat fuzzy and have poor resolution

front 30

44) The purpose of the ocular lens is to

A) improve resolution.

B) magnify the image from the objective lens.

C) decrease the refractive index.

D) increase the light.

E) decrease the light.

back 30

B) magnify the image from the objective lens.

front 31

45) In microscopy, the term resolution

A) refers to the ability to distinguish fine structure and detail in a specimen.

B) is the same as the total magnification of a specimen.

C) is improved when longer wavelengths of light are employed.

D) is only observed in stained specimens.

E) refers to magnification when using the electron microscope.

back 31

A) refers to the ability to distinguish fine structure and detail in a specimen.