Print Options

Card layout: ?

← Back to notecard set|Easy Notecards home page

Instructions for Side by Side Printing
  1. Print the notecards
  2. Fold each page in half along the solid vertical line
  3. Cut out the notecards by cutting along each horizontal dotted line
  4. Optional: Glue, tape or staple the ends of each notecard together
  1. Verify Front of pages is selected for Viewing and print the front of the notecards
  2. Select Back of pages for Viewing and print the back of the notecards
    NOTE: Since the back of the pages are printed in reverse order (last page is printed first), keep the pages in the same order as they were after Step 1. Also, be sure to feed the pages in the same direction as you did in Step 1.
  3. Cut out the notecards by cutting along each horizontal and vertical dotted line
To print: Ctrl+PPrint as a list

25 notecards = 7 pages (4 cards per page)

Viewing:

Self Test: Part G

front 1

What is the SI unit of radiation measurement for absorbed dose?

back 1

Gray

front 2

Which term is replacing "exposure" to describe skin dose?

back 2

Air kerma

front 3

What is the annual whole body effective dose (ED) for a technologist?

back 3

50 mSv or 5 rem

front 4

What is the cumulative lifetime ED for a 25 year old technologist?

back 4

250 mSv

front 5

What is the annual ED limit for an individual younger than 18 years of age?

back 5

1 mSv or 0.1 rem

front 6

The federal set maximum limit on exposure rates for intensified fluoroscopy units is:

back 6

10 R/minutes

front 7

For most modern equipment, the average fluoroscopy tabletop exposure rate is:

back 7

1 and 3 R/minutes

front 8

What is the primary purpose of x-ray tube filtration?

back 8

Absorb lower (unusable) energy x-rays

front 9

Which of the following results in the highest ED for females (assuming no specific area shields are used)?

back 9

AP thoracic spine (14 X 17 inch collimation)

front 10

The use of a 1-mm lead equivalent gonadal shield reduces the gonadal dose by _________ if the gonads are within the primary x-ray field.

back 10

50% - 90%

front 11

Which type of shield is ideal when the affected tissue is part of a sterile field?

back 11

Shadow shield

front 12

True/False:

Low kV and high mAs techniques greatly reduce patient dose compared with high kV and low mAs techniques.

back 12

False

front 13

True/False:

The total ED for females on an AP chest projection is more than double for that of a PA chest.

back 13

True

front 14

True/False:

The use of a positive beam limiting (PBL) collimator is no longer required by the FDA for new x-ray equipment manufactured after 1994.

back 14

True

front 15

True/False:

Collimators must be accurate within 5% of the selected SID.

back 15

False

front 16

Which of the following is not one of the cardinal principles of radiation protection?

Distance

Time

Shielding

Collimation

back 16

Collimation

front 17

Which one of the following changes will best reduce patient dose?

Decrease kV and increase mAs

Increase kV and lower mAs

Using a grid

Increase mAs and lower kV

back 17

Increase kV and lower mAs

front 18

Where is the safest place for the technologist to stand during a fluoroscopic procedure?

back 18

behind the radiologist

front 19

Which of the following protection devices must be employed during a fluoroscopic procedure?

Bucky slot shield

Lead gloves

Compensating filter

Restraining devices

back 19

Bucky slot shield

front 20

The ED for a pregnant technologist per month is:

back 20

0.5 mSv (0.05 rem)

front 21

True/False:

A fetal personnel dosimeter is worn at the level of the waist by a pregnant technologist during fluoroscopy.

back 21

True

front 22

True/False:

All administrative staff in the radiology department must wear a personnel dosimeter even if not involved with patient care directly.

back 22

False

front 23

True/False:

The ICRP and ARC have determined that the "10-day rule" is obsolete for procedures of the abdomen and pelvis.

back 23

True

front 24

True/False:

ALARA does not apply to digital imaging.

back 24

False

front 25

True/False:

Using a different algorithm to process an overexposed CR image is an acceptable and ethical practice.

back 25

False