Print Options

Card layout: ?

← Back to notecard set|Easy Notecards home page

Instructions for Side by Side Printing
  1. Print the notecards
  2. Fold each page in half along the solid vertical line
  3. Cut out the notecards by cutting along each horizontal dotted line
  4. Optional: Glue, tape or staple the ends of each notecard together
  1. Verify Front of pages is selected for Viewing and print the front of the notecards
  2. Select Back of pages for Viewing and print the back of the notecards
    NOTE: Since the back of the pages are printed in reverse order (last page is printed first), keep the pages in the same order as they were after Step 1. Also, be sure to feed the pages in the same direction as you did in Step 1.
  3. Cut out the notecards by cutting along each horizontal and vertical dotted line
To print: Ctrl+PPrint as a list

25 notecards = 7 pages (4 cards per page)

Viewing:

1 Exam Prep 2017 Florida Building Code -Energy Conservation Questions and Answers

front 1

A steam type heating system has a fluid design operating temperature of 275 degrees Fahrenheit and a nominal pipe diameter of one inch. The minimum pipe insulation should be how many inches?

back 1

4.0

front 2

A steam type heating system has a fluid design operating temperature of 275 degrees Fahrenheit and a nominal pipe diameter of one and one half inches. The minimum pipe insulation should be how many inches?

back 2

4.5

front 3

Residential sliding glass doors shall have an air infiltration rate of no more than _______________ cfm per square foot.

back 3

0.3

front 4

The estimated total cooling of a central air conditioner in Btu's during its normal usage period for cooling (not to exceed 12 months) divided by the total electric energy input in watt-hours during the same period is
called the _______________ Energy Efficiency Ratio.

back 4

Seasonal

front 5

The outer jacket of a flexible duct section _______________ be interposed between the flange of the duct collar fitting and the flexible duct.

back 5

Shall not

front 6

The maximum air leakage in CFM’s for a 3 ft. by 7 ft. commercial glazed swinging entrance door is

back 6

21

front 7

Opaque Swinging doors require a U-value of _______________ when installed in a climate zone 3, group R?

back 7

U-0.61

front 8

Supply ducts in residential attics shall be insulated to a minimum of

back 8

R-8

front 9

Energy compliance is made part of the plans and requires certification by the

back 9

Code Official

front 10

Mass common walls require a minimum R-value of

back 10

6

front 11

When using R-value in thermal resistance designations, the term R-value means?

back 11

The inverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces, under steady state conditions per unit area.

front 12

Which of the following does not require code compliance by license or registration?

back 12

Single family residential

front 13

Duval county is in moisture regime?

back 13

2A

front 14

A wood house built in climate zone 3 will require exterior wood frame walls to have an R-value of

back 14

20

front 15

The coefficient of heat transmission (air to air) through a building component or assembly, equal to the time rate of heat flow per unit area and unit temperature difference between the warm side and cold side air films is referred to as

back 15

U-factor

front 16

___________________ shall not contain electrical, plumbing or mechanical systems which have
been designed to accommodate the future installation of heating or cooling equipment.

back 16

Low energy buildings

front 17

___________________ is defined as, the basement walls, exterior walls, floor, roof, and any other building elements that enclose conditioned space. This boundary also includes the boundary between conditioned space and exempt or unconditioned space.

back 17

Building thermal envelope

front 18

___________________ is the ratio of the solar heat gain entering the space through the fenestration
assembly to the incident solar radiation. Solar heat gain includes directly transmitted solar heat and absorbed solar radiation which is then reradiated, conducted or convected into the space.

back 18

Solar heat gain coefficiency

front 19

The U Factor for an uninsulated metal door is

back 19

1.20

front 20

Broward county is in which designation for climate zone, moisture regime and warm humid designation?

back 20

1A warm-humid

front 21

The default glazed fenestration U-factor for a double pane metal skylight is

back 21

1.30

front 22

The thickness of blown-in or sprayed roof/ceiling insulation (fiberglass or cellulose) shall be written on markers that are installed at least one for every ___________ throughout the attic space.

back 22

300 square feet

front 23

___________________ is energy derived from solar radiation, wind, waves, tides, landfill gas, biomass, or the internal heat of the earth. The energy system providing on-site renewable energy shall be located on the project site.

back 23

on-site renewable energy

front 24

Mechanical system piping in residential homes capable of carrying fluids above 105 F or below 55 F shall be insulated to a minimum of

back 24

R-3

front 25

In a commercial structure the skylight area shall not exceed _____ percent of the gross roof area.

back 25

3